Power Cable
<Upper layer
Power Cable
Construction Specification
| Item | Material | Diameter(mm) |
|---|---|---|
| Inner Conductor | Stranded tin plated copper | 28×0.25 Nom.Φ1.54 |
| Dielectric | SEBS(TPE=Thermoplastic elastomer) | 2.4±0.10 |
| (Red, Black) | ||
| Filling | Two polyester filler | 1.6±0.10 |
| Cabling | Foll tape PET-band | |
| Shield | Tin plated copper wire(coverage:75%) | 5.5±0.20 |
| Jacket | Grey LSZH-material | 7.2±0.20 |
Electrical Characteristics
| Test voltage(KV) | Nom.2.0 |
| Resistance conductor(Ω/km) | Nom.13.5 |
| Insulation resistance | ≥200MΩ·km |
| Current load | ≤10A |
Mechanical and Environmental Characteristics
| Temperature range(℃) | -20 to +80 |
| Pull force | ≤130N |
| Bending radius once(mm) | 35 |
| repeated bending radius(mm) | 60 |
| Weight(Kg/Km) | 62 |
SHARE: