Aviation Military Installation Wire
Aviation Military Installation Wire
Performance
| Rated Voltage | 1000V |
| Rated Temperature | Sliver plated conductor with any jacket: -55 to +200℃ |
| Nickel plated conductor with PTFE jacket: -55 to +260℃ |
Construction
| Dielectric | PTFE |
| Conductor | Sliver plated copper or Nickel plated copper |
| Shield | Silver Plated Copper Braid (85%) |
| Jacket | FEP or PTFE tape |
| Colour | MIL-STD-104 Standard |
Size, Resistance and Weight -- 1 core
| Line Group | Shield Diameter (nom., mm) | Jacket Diameter (nom., mm) | Weight (kg/km) |
|
|---|---|---|---|---|
| AWG | Stranding | |||
| 8 | 133/29 | 5.77 | 6.48 | 138.0 |
| 10 | 37/26 | 4.19 | 4.90 | 78.7 |
| 12 | 19/25 | 3.66 | 4.22 | 57.0 |
| 14 | 19/27 | 3.18 | 3.73 | 40.8 |
| 16 | 19/29 | 2.79 | 3.30 | 30.4 |
| 18 | 19/30 | 2.54 | 3.05 | 25.4 |
| 20 | 19/32 | 2.29 | 2.74 | 20.5 |
| 22 | 19/34 | 2.08 | 2.54 | 16.2 |
| 24 | 19/38 | 1.99 | 2.39 | 13.7 |
| 26 | 19/38 | 1.68 | 2.13 | 10.6 |
| 28 | 7/36 | 1.55 | 2.01 | 9.45 |
| 30 | 7/38 | 1.50 | 1.96 | 8.59 |
| 32 | 7/40 | 1.45 | 1.91 | 8.11 |
Size, Resistance and Weight -- 2 cores
| Line Group | Shield Diameter (nom., mm) | Jacket Diameter (nom., mm) | Weight (kg/km) |
|
|---|---|---|---|---|
| AWG | Stranding | |||
| 8 | 133/29 | 11.1 | 11.94 | 283 |
| 10 | 37/26 | 7.80 | 8.56 | 149 |
| 12 | 19/25 | 6.73 | 7.34 | 106 |
| 14 | 19/27 | 5.77 | 6.38 | 76.0 |
| 16 | 19/29 | 5.00 | 5.56 | 56.2 |
| 18 | 19/30 | 4.50 | 5.05 | 46.7 |
| 20 | 19/32 | 3.99 | 4.55 | 36.6 |
| 22 | 19/34 | 3.58 | 4.14 | 29.5 |
| 24 | 19/38 | 3.28 | 3.84 | 24.6 |
| 26 | 19/38 | 3.02 | 3.58 | 21.1 |
| 28 | 7/36 | 2.77 | 3.33 | 18.9 |
| 30 | 7/38 | 2.67 | 3.23 | 16.5 |
Size, Resistance and Weight -- 3 cores
| Line Group | Shield Diameter (nom., mm) | Jacket Diameter (nom., mm) | Weight (kg/km) |
|
|---|---|---|---|---|
| AWG | Stranding | |||
| 8 | 133/29 | 11.9 | 12.72 | 400 |
| 10 | 37/26 | 8.34 | 9.15 | 210 |
| 12 | 19/25 | 7.19 | 7.85 | 150 |
| 14 | 19/27 | 6.15 | 6.76 | 106 |
| 16 | 19/29 | 5.34 | 5.94 | 78.0 |
| 18 | 19/30 | 4.79 | 5.35 | 63.2 |
| 20 | 19/32 | 4.24 | 4.80 | 48.8 |
| 22 | 19/34 | 3.81 | 4.36 | 38.7 |
| 24 | 19/38 | 3.48 | 3.04 | 31.7 |
| 26 | 19/38 | 3.21 | 3.76 | 27.2 |
| 28 | 7/36 | 2.93 | 3.49 | 23.5 |
| 30 | 7/38 | 2.82 | 3.38 | 20.5 |
| 32 | 7/40 | 2.71 | 3.27 | 19.0 |
Size, Resistance and Weight -- 4 cores
| Line Group | Shield Diameter (nom., mm) | Jacket Diameter (nom., mm) | Weight (kg/km) |
|
|---|---|---|---|---|
| AWG | Stranding | |||
| 8 | 133/29 | 13.2 | 14.4 | 534 |
| 10 | 37/26 | 9.28 | 10.1 | 271 |
| 12 | 19/25 | 7.99 | 8.70 | 195 |
| 14 | 19/27 | 6.83 | 7.49 | 136 |
| 16 | 19/29 | 5.91 | 6.52 | 98.4 |
| 18 | 19/30 | 5.30 | 5.86 | 79.5 |
| 20 | 19/32 | 4.69 | 5.24 | 60.7 |
| 22 | 19/34 | 4.20 | 4.75 | 47.5 |
| 24 | 19/38 | 3.83 | 4.39 | 38.7 |
| 26 | 19/38 | 3.52 | 4.08 | 26.5 |
| 28 | 7/36 | 3.22 | 3.78 | 21.0 |
| 30 | 7/38 | 3.09 | 3.65 | 18.7 |
| 32 | 7/40 | 2.97 | 3.53 | 17.1 |
SHARE: